Communication Challenge
In industrial automation systems, an EtherCAT-based PLC may need to communicate with existing CANopen devices, such as distributed I/O modules, motor controllers, or other CANopen-enabled equipment.
However, the EtherCAT master cannot directly manage devices on a separate CANopen network without an appropriate communication gateway.
Integrating CANopen-based devices into an EtherCAT automation system
Solution
The GCAN-GT-8221-COM operates as an EtherCAT slave on the EtherCAT side and provides CANopen Master functionality on the CAN side.
It enables the EtherCAT control system to communicate with CANopen slave devices through the gateway, supporting CANopen network communication and PDO data exchange.
Products Used
GCAN-GT-8221: Level 2 Raw CAN Routing & Level 4 CANopen Master Management.
- 1 × GCAN-GT-8221-COM EtherCAT to CANopen Gateway
- 1 × EtherCAT Master PLC or Controller
- CANopen slave devices (distributed I/O modules, motor controllers or other CANopen devices)
- Ethernet CAT5 cable
- CAN bus twisted-pair cable
Interfaces & Protocols
- EtherCAT Master ↔ GCAN-GT-8221-COM: EtherCAT · Slave
- GCAN-GT-8221-COM ↔ CANopen Devices: CANopen · Master/Slave
- CANopen Communication: PDO · Node Guarding · Emergency Messages
- Power Supply: 24 V DC
How Data Flows
- EtherCAT Master → GCAN-GT-8221-COM: The EtherCAT master exchanges data with the gateway through the EtherCAT network.
- GCAN-GT-8221-COM → CANopen Devices: The gateway manages communication with connected CANopen slave devices.
- CANopen Devices → GCAN-GT-8221-COM: CANopen slave devices provide process data through PDO communication.
- GCAN-GT-8221-COM → EtherCAT Master: The gateway enables CANopen device data to be exchanged with the EtherCAT master.
Result
The GCAN-GT-8221-COM allows CANopen-based equipment to be integrated into an EtherCAT control architecture.
By providing CANopen Master functionality, it enables an EtherCAT master to communicate with existing CANopen slave devices, simplifying the integration of distributed CANopen equipment into centralized industrial control systems.
Choose the Right Industrial CAN Gateway
| Model | Processing Level | CAN-Side Role | Can it act as a Master? | Sub-models / Programmability | Interfaces | Application | |
| GCAN-204 | Register mapping (Not transparent) | Fixed Modbus RTU Slave | No. Modbus RTU Slave only. | Single fixed firmware. Free config software, zero programming. | 1× RS485, 1× CAN 2.0A/B |
PLC/HMI (Modbus master) reading CAN sensors; legacy retrofits. | |
| GCAN-205 | Register mapping (Not transparent). | Fixed Modbus TCP Slave | No. Modbus TCP Slave only. | Single fixed firmware. Free config software. | 1× Ethernet, 1× CAN 2.0A/B |
SCADA/HMI reading CAN devices over Ethernet. | |
| GCAN-208 | Pure physical-layer passthrough. | No protocol role | No. No protocol stack. | Sub-models: 208-1, 208-2, 208-2F. | 1–2× Fiber, 1–2× CAN 2.0A/B |
Long-distance CAN extension, high EMI isolation. | |
|
Socket-level transparent transmission. | No protocol role | No. Data pipe only. | Single unit. Can work in pairs as a wireless CAN repeater. | 2× CAN, 1× Ethernet, 1× WiFi |
Wireless CAN access, mobile debugging. | |
| GCAN-212B | Socket-level transparent transmission. | No protocol role | No. Data pipe only. | Single unit (DIN-rail). | 2× CAN, 1× Ethernet |
Dual-channel CAN to Ethernet inside cabinets. | |
| GCAN-GT-8221 | Splits by sub-model: | EtherCAT Slave → CAN: |
|
Sub-models: -CAN, -COM. Fixed firmware. | 2× EtherCAT (daisy-chain), 1× CAN |
EtherCAT PLC integrating existing CANopen slave devices. | |
| • -CAN: Raw passthrough. | • -CAN: Passthrough | ||||||
| • -COM: CANopen slave stack (Semantic parsing). | • -COM: CANopen Slave | ||||||
| GCAN-GT-8321 | Splits by sub-model (Most comprehensive): | Profinet Slave → CAN: | Profinet side: No. | Sub-models: -CAN, -COM, -COS, -MRTUM, -MRTUS, -MTCPS, -PROG. | 2× Profinet, 1× CAN, 1× RS485, 1× Ethernet (varies) |
Siemens PLC integrating CANopen drives; active CANopen network management. | |
| • -CAN: Raw passthrough. | • -CAN: Passthrough | CAN side: NO | |||||
| • -COM: CANopen Slave. | • -COM: CANopen Slave | CAN side: NO | |||||
| • -COS: CANopen Master (NMT, node monitoring). | • -COS: CANopen Master | CAN side: -COS YES | |||||
| • -PROG: Programmable. | User-defined (Master/Slave configurable) | Yes (Configurable via program) | |||||
| GCAN-GT-415 | Full programmable semantic processing. | Configurable via program | Yes, fully configurable. CANopen & Modbus Master/Slave. | No fixed sub-models. Programmable via OpenPCS (IEC 61131-3). | 2× CAN, Ethernet, RS485, RS232, 4G, WiFi | Multi-protocol mixing, non-standard logic, remote upload (acts as a mini-PLC). |