Skip to content
Product Application
Product Application

GCAN-204 Application: Modbus PLC to CAN Device Command Transmission

Published on Nov 25, 2026

Modbus RTU PLC to CAN Device Communication · PLC Command Transmission · Configurable Register Mapping · CAN 2.0A/B · GCAN-204

GCAN-204 Application: Modbus PLC to CAN Device Command Transmission

Communication Challenge

An existing PLC-based control system needs to send commands to a CAN-connected device, such as a controller or actuator. However, the PLC communicates through Modbus RTU and does not have a native CAN interface.

写作 GCAN-204 Modbus RTU to CAN gateway transmitting PLC commands to CAN-based devices

GCAN-204 converts configured Modbus register write operations into CAN frames for communication with CAN-based controllers and actuators.

Solution

Transmit PLC Commands to CAN-Based Devices

Products Used

GCAN-204 Modbus RTU slave to CAN gateway product image, RS485 to CAN industrial protocol converter with CAN 2.0A/B, 1500 V isolation and DIN-rail mounting; Modbus RTU slave only, no Modbus master function.

The GCAN-204 is an industrial Modbus RTU slave to CAN gateway with RS485 and CAN interfaces, designed for DIN-rail mounting and protocol conversion between an existing Modbus master and CAN devices.

Products Used
  • GCAN-204 Modbus RTU Slave to CAN Gateway
  • Modbus RTU PLC
  • CAN-based controller or actuator

Interfaces & Protocols

  • PLC Side: Modbus RTU over RS485
  • Device Side: CAN 2.0A/B

How Data Flows

GCAN-204 Modbus RTU to CAN gateway data flow diagram showing a PLC writing data to Modbus registers, which are mapped to CAN frames and transmitted to a target CAN device.

Data flow from PLC Modbus registers to CAN devices through the GCAN-204 gateway.

  • The PLC writes command data to the configured Modbus registers.
  • GCAN-204 processes the written data according to the predefined CAN mapping.
  • The gateway generates and transmits the corresponding CAN frames.
  • The target CAN device receives the frames and performs its programmed operation.

Result

The PLC can send predefined commands to CAN-based devices using standard Modbus RTU register operations, without requiring a native CAN interface.

Choose the Right Industrial CAN Gateway

Model  Processing Level CAN-Side Role Can it act as a Master? Sub-models / Programmability Interfaces Application
GCAN-204 Register mapping (Not transparent) Fixed Modbus RTU Slave No. Modbus RTU Slave only. Single fixed firmware. Free config software, zero programming. 1× RS485,
1× CAN 2.0A/B
PLC/HMI (Modbus master) reading CAN sensors; legacy retrofits.
GCAN-205 Register mapping (Not transparent). Fixed Modbus TCP Slave No. Modbus TCP Slave only. Single fixed firmware. Free config software. 1× Ethernet,
1× CAN 2.0A/B
SCADA/HMI reading CAN devices over Ethernet.
GCAN-208 Pure physical-layer passthrough. No protocol role No. No protocol stack. Sub-models: 208-1, 208-2, 208-2F. 1–2× Fiber,
1–2× CAN 2.0A/B
Long-distance CAN extension, high EMI isolation.
GCAN-211
Socket-level transparent transmission. No protocol role No. Data pipe only. Single unit. Can work in pairs as a wireless CAN repeater. 2× CAN,
1× Ethernet,
1× WiFi
Wireless CAN access, mobile debugging.
GCAN-212B Socket-level transparent transmission. No protocol role No. Data pipe only. Single unit (DIN-rail). 2× CAN,
1× Ethernet
Dual-channel CAN to Ethernet inside cabinets.
GCAN-GT-8221 Splits by sub-model: EtherCAT Slave → CAN:
No on EtherCAT side. Fixed EtherCAT slave.
Sub-models: -CAN, -COM. Fixed firmware. 2× EtherCAT (daisy-chain),
1× CAN
EtherCAT PLC integrating existing CANopen slave devices.
• -CAN: Raw passthrough. • -CAN: Passthrough
• -COM: CANopen slave stack (Semantic parsing). • -COM: CANopen Slave
GCAN-GT-8321 Splits by sub-model (Most comprehensive): Profinet Slave → CAN: Profinet side: No. Sub-models: -CAN, -COM, -COS, -MRTUM, -MRTUS, -MTCPS, -PROG. 2× Profinet,
1× CAN,
1× RS485,
1× Ethernet (varies)
Siemens PLC integrating CANopen drives; active CANopen network management.
• -CAN: Raw passthrough. • -CAN: Passthrough CAN side:  NO
• -COM: CANopen Slave. • -COM: CANopen Slave CAN side:  NO
• -COS: CANopen Master (NMT, node monitoring). • -COS: CANopen Master CAN side: -COS YES
• -PROG: Programmable. User-defined (Master/Slave configurable) Yes (Configurable via program)
GCAN-GT-415 Full programmable semantic processing. Configurable via program Yes, fully configurable. CANopen & Modbus Master/Slave. No fixed sub-models. Programmable via OpenPCS (IEC 61131-3). 2× CAN, Ethernet, RS485, RS232, 4G, WiFi Multi-protocol mixing, non-standard logic, remote upload (acts as a mini-PLC).

Inquire Us or Request a Quote

We will get back to you shortly within 24 business hours.

Products Category Showcase
Remarks: Products are supported by CE-EMC testing in accordance with EU Directive 2014/30/EU, as well as RoHS testing in accordance with IEC 62321-3-1:2013.
Min 25 characters Max characters left: 750
📁

Upload your file (Optional)