GCAN-204 Application: CAN Data Acquisition via Modbus RTU

Published on Nov 25, 2026

CAN Sensor Data Acquisition · Modbus RTU PLC Integration · Configurable CAN-to-Modbus Register Mapping · CAN 2.0A/B · GCAN-204

GCAN-204 Application: CAN Data Acquisition via Modbus RTU

Communication Challenge

The control system uses a Modbus RTU PLC, while field sensors or monitoring devices communicate through CAN. The PLC cannot directly access CAN messages, making it difficult to collect field data within the existing control system.

GCAN-204 Modbus RTU to CAN gateway connecting CAN-based sensors to a Modbus RTU PLC

GCAN-204 enables a Modbus RTU PLC to access data from CAN-based sensors through configurable register mapping.

Solution

Integratie CAN-Based Sensors with a Modbus RTU PLC

Products Used

GCAN-204 Modbus RTU slave to CAN gateway product image, RS485 to CAN industrial protocol converter with CAN 2.0A/B, 1500 V isolation and DIN-rail mounting; Modbus RTU slave only, no Modbus master function.

The GCAN-204 is an industrial Modbus RTU slave to CAN gateway with RS485 and CAN interfaces, designed for DIN-rail mounting and protocol conversion between an existing Modbus master and CAN devices.

Products Used
  • GCAN-204 Modbus RTU Slave to CAN Gateway
  • Modbus RTU PLC
  • CAN-based sensor or monitoring devices

Interfaces & Protocols

  • PLC Side: Modbus RTU over RS485
  • Field Device Side: CAN 2.0A/B

How Data Flows

GCAN-204 CAN to Modbus RTU data flow diagram showing CAN devices transmitting data frames to the gateway, which maps the data to Modbus registers for PLC monitoring and processing.

Data flow from CAN devices to a PLC through GCAN-204 using Modbus RTU register mapping.

  • CAN devices transmit data frames with predefined CAN IDs.
  • The GCAN-204 receives the specified CAN frames and stores the -mapped data in its Modbus register table.
  • The PLC reads the corresponding registers using Modbus RTU commands.
  • The CAN data becomes available to the PLC for monitoring and further control-system processing.

Result

CAN-based field data can be integrated into an existing Modbus RTU control system without replacing the PLC or requiring it to directly process CAN frames.

Choose the Right Industrial CAN Gateway

Model Processing Level CAN-Side Role Can it act as a Master? Sub-models / Programmability Interfaces Application
GCAN-204 Register mapping (Not transparent) Fixed Modbus RTU Slave No. Modbus RTU Slave only. Single fixed firmware. Free config software, zero programming. 1× RS485,
1× CAN 2.0A/B
PLC/HMI (Modbus master) reading CAN sensors; legacy retrofits.
GCAN-205 Register mapping (Not transparent). Fixed Modbus TCP Slave No. Modbus TCP Slave only. Single fixed firmware. Free config software. 1× Ethernet,
1× CAN 2.0A/B
SCADA/HMI reading CAN devices over Ethernet.
GCAN-208 Pure physical-layer passthrough. No protocol role No. No protocol stack. Sub-models: 208-1, 208-2, 208-2F. 1–2× Fiber,
1–2× CAN 2.0A/B
Long-distance CAN extension, high EMI isolation.
GCAN-211
Socket-level transparent transmission. No protocol role No. Data pipe only. Single unit. Can work in pairs as a wireless CAN repeater. 2× CAN,
1× Ethernet,
1× WiFi
Wireless CAN access, mobile debugging.
GCAN-212B Socket-level transparent transmission. No protocol role No. Data pipe only. Single unit (DIN-rail). 2× CAN,
1× Ethernet
Dual-channel CAN to Ethernet inside cabinets.
GCAN-GT-8221 Splits by sub-model: EtherCAT Slave → CAN:
No on EtherCAT side. Fixed EtherCAT slave.
Sub-models: -CAN, -COM. Fixed firmware. 2× EtherCAT (daisy-chain),
1× CAN
EtherCAT PLC integrating existing CANopen slave devices.
• -CAN: Raw passthrough. • -CAN: Passthrough
• -COM: CANopen slave stack (Semantic parsing). • -COM: CANopen Slave
GCAN-GT-8321 Splits by sub-model (Most comprehensive): Profinet Slave → CAN: Profinet side: No. Sub-models: -CAN, -COM, -COS, -MRTUM, -MRTUS, -MTCPS, -PROG. 2× Profinet,
1× CAN,
1× RS485,
1× Ethernet (varies)
Siemens PLC integrating CANopen drives; active CANopen network management.
• -CAN: Raw passthrough. • -CAN: Passthrough CAN side:  NO
• -COM: CANopen Slave. • -COM: CANopen Slave CAN side:  NO
• -COS: CANopen Master (NMT, node monitoring). • -COS: CANopen Master CAN side: -COS YES
• -PROG: Programmable. User-defined (Master/Slave configurable) Yes (Configurable via program)
GCAN-GT-415 Full programmable semantic processing. Configurable via program Yes, fully configurable. CANopen & Modbus Master/Slave. No fixed sub-models. Programmable via OpenPCS (IEC 61131-3). 2× CAN, Ethernet, RS485, RS232, 4G, WiFi Multi-protocol mixing, non-standard logic, remote upload (acts as a mini-PLC).

Inquire Us or Request a Quote

We will get back to you shortly within 24 business hours.

Products Category Showcase
Remarks: Products are supported by CE-EMC testing in accordance with EU Directive 2014/30/EU, as well as RoHS testing in accordance with IEC 62321-3-1:2013.
Min 25 characters Max characters left: 750
📁

Upload your file (Optional)

No file chosen

Supported formats: PDF, Images (JPG, PNG, WEBP), CAD drawings (DWG, STEP, IGES), Documents (Word, Excel), ZIP, RAR, etc.

Max file size: 25MB

Got multiple files? Put all your files in a folder and compress the folder into a ZIP or RAR file.

Alternatively, send your RFQ directly to [email protected]

Security Quiz: 7 + 8 = ? *