Skip to content
GCAN Banner
GCAN Model: GCAN-I/O-8101

GCAN-I/O-8101 Modbus Remote I/O Coupler

Up to 32 I/O Modules · Ethernet & RS485 Ports · Auto-Configuration · Modbus TCP/RTU

🔵 Overview
GCAN-IO-8101:

  • The GCAN-IO-8101 is an industrial-grade Modbus Remote I/O Coupler designed to highly expand I/O capabilities and simplify wiring over both Ethernet and serial networks.
  • Compliant with standard Modbus protocols (Modbus TCP & Modbus RTU), it acts as a reliable slave node, supporting seamless integration with a wide range of PLCs, SCADA systems, and HMI devices.
  • Equipped with 1 Ethernet port and 1 RS485 port, auto-configuration, and wide operating temperature (-40°C to +85°C), it supports up to 32 GC series terminal modules (Digital, Analog, RTD/TC), ensuring robust data transmission in harsh industrial environments.

I/O Expansion Module:

  • The I/O expansion modules on this page are for the GCAN-IO-8101 / 8X01 series 18-pin system only. They cannot operate independently and must be used with the GCAN-IO-8101 bus adapter. They must not be mixed with GCAN-IO-8300 / 8X00 series 8/16-pin modules.
  • A complete node consists of a GCAN-IO-8101 adapter, compatible 18-pin I/O expansion modules, and one GC-0002 bus end terminal at the far right end. The adapter-to-I/O interface is the GCAN GC-Bus, not a universal standard backplane. Third-party compatibility must be confirmed by the factory.
  • Some digital output modules, such as GC-2416 and GC-2516, require an independent 24 VDC supply. Please check before selection.

GC-0002 Bus End Terminal:

  • One GC-0002 bus end terminal is required per GCAN-IO-8101 / 18-pin node and must be installed at the far right end, with the direction marked “UP” as shown in the manual. It must be installed; otherwise, I/O devices will not work.
  • GC-0002 is required per node, not per I/O module. It is not interchangeable with GC-0001, which is for the GCAN-IO-8300 / 8/16-pin series only.
  • Do not wire GC-0002 as a normal I/O module. Keep its top structure in the factory state and do not connect wires or make modifications.

🔵 Critical Selection Guide: Expansion & Compatibility

  • Before selecting your I/O modules, please note the hardware configuration features for your specific application:
  • Expansion Capacity: 1 Coupler + Up to 32 GC series I/O modules + 1 Terminal Module (GC0002). Auto-configuration eliminates the need for complex PC parameter settings.
  • Network Topology: Supports both Modbus TCP (via RJ45 Ethernet) and Modbus RTU (via RS485). The RS485 bus is ideal for long-distance, anti-interference serial networks.
  • Wiring & Power: Screwdriver-push terminals for easy wiring. 24V DC power input with tolerance of -15%/+20%.
  • PLC Compatibility: Universally compatible as a Modbus slave for almost all industrial controllers that support Modbus TCP or RTU master protocols.

🔵 Core Application Scenarios & Solutions
💡 Scenario 1: Distributed I/O Expansion for Factory Automation
😟 The Challenge: Upgrading existing machinery or extending I/O points in large factory floors often requires running thick multi-core cables from field sensors back to the central PLC cabinet. This is expensive, labor-intensive, and prone to electromagnetic interference.
🔧 The Solution: The GCAN-IO-8101 is installed locally near the field sensors/actuators. It gathers data from up to 32 expansion modules and transmits it seamlessly to the central control system via a single standard Ethernet cable (Modbus TCP) or a twisted pair cable (Modbus RTU), dramatically reducing long-distance wiring costs and improving signal reliability.

💡 Scenario 2: Long-Distance Field Data Acquisition & Anti-Interference
😟 The Challenge: In heavy industrial environments, sensors are often distributed across long distances and placed near high-noise equipment like inverters and large motors. Long analog cables easily suffer from signal attenuation and ground loop interference, leading to inaccurate data.
🔧 The Solution: Utilizing the RS485 (Modbus RTU) interface, the GCAN-IO-8101 digitizes analog and discrete signals locally and transmits them over long distances using standard twisted-pair cables. Combined with its wide operating temperature range (-40°C to +85°C) and robust industrial design, it ensures highly reliable data transmission in harsh environments.

💡 Scenario 3: Building Automation (HVAC / BAS) & Distributed Monitoring
😟 The Challenge: In HVAC systems, water pump rooms, or ventilation units, field devices are scattered across different floors and mechanical rooms. Traditional centralized wiring is costly, and the installation space inside local control cabinets is usually very limited.
🔧 The Solution: With its compact design and standard DIN rail mounting, the GCAN-IO-8101 fits easily into space-constrained electrical boxes. It perfectly interfaces with Building Management Systems (BMS) or SCADA via Modbus TCP/RTU, enabling distributed data collection for temperature, pressure, and status signals across the building.

💡 Scenario 4: Renewable Energy & Municipal Telemetry (SCADA)
😟 The Challenge: Solar farms, wind turbines, and remote water treatment pump stations operate in outdoor, unattended environments with extreme weather conditions. Maintenance engineers require a highly reliable, low-maintenance solution for remote data uploading.
🔧 The Solution: The GCAN-IO-8101 acts as a robust edge node. It collects data from local sensors and transmits it to the central SCADA or cloud platform using Modbus protocols. The auto-configuration feature eliminates on-site programming, significantly reducing the maintenance frequency and labor costs for remote sites.

PART / MODEL IDENTIFICATION & TECHNICAL DOSSIER Part / Model No.: GCAN-I/O-8101

Front view of GCAN-I/O-8101 Modbus Remote I/O Coupler with Ethernet and RS485 interfaces.

KEY FEATURE

Modbus Remote I/O Coupler

Up to 32 GC Series I/O Modules (Digital, Analog, Temperature)
Standard Modbus TCP/RTU Slave for seamless SCADA, PLC, and HMI integration
Auto-Configuration for plug-and-play setup without complex PC programming
Push-in power terminals for fast, screwdriver-assisted wiring
Dual communication interfaces (1x RJ45 Ethernet & 1x RS485) for flexible networking
Operating Temp. from -40°C to +85°C
DIN-rail mounting, and USB port for firmware upgrades

Find Your Modbus Remote I/O Solution by Application

◆ Application 1: My PLC or machine has run out of built-in I/O points, and I need a flexible expansion. (Keywords: PLC I/O expansion, machine retrofit)
👉 Product model: GCAN-IO-8101
💡 How it works:
➤ Role: Acts as a modular Modbus Remote I/O Coupler (Slave) for universal automation systems.
➤ Connection: Connects seamlessly to main PLCs or controllers via standard Ethernet (Modbus TCP) or RS485 (Modbus RTU). You can stack up to 32 GC series modules (DI, DO, AI, AO, RTD/TC) on the right side of the coupler.
➤ Data Processing: Features auto-configuration. The master system simply reads/writes registers via standard Modbus functions, mapping the expanded I/O data directly without complex PC parameter settings or extra programming.

◆ Application 2: The sensors are far away from the main control cabinet, and direct wiring is too expensive and noisy. (Keywords: long-distance RS485 data acquisition, field remote I/O)
👉 Product model: GCAN-IO-8101
💡 How it works:
➤ Role: Acts as a decentralized field-level I/O node.
➤ Connection: Installed locally near the sensors or actuators outside the control cabinet. Utilizes the RS485 port to daisy-chain multiple nodes, or the RJ45 port for Ethernet networks.
➤ Signal Transmission: Field analog and digital signals are collected locally and transmitted to the central controller via standard twisted-pair cables (Modbus RTU) or Ethernet. This dramatically saves long-distance cabling costs and uses robust Modbus protocols to ensure stable data transmission in noisy factory environments.

◆ Application 3: My HVAC, pump stations, or building devices are scattered, and local cabinet space is limited. (Keywords: Building automation Modbus I/O, HVAC BMS integration)
👉 Product model: GCAN-IO-8101
💡 How it works:
➤ Role: Acts as a compact DIN-rail Modbus I/O coupler for building automation (BAS) and distributed monitoring.
➤ Connection: Its slim design fits easily into space-constrained electrical boxes on different floors or mechanical rooms.
➤ System Integration: Connects seamlessly with Building Management Systems (BMS) or local SCADA via Modbus TCP or RTU. It collects data for temperature, pressure, and equipment status, enabling reliable distributed control across the facility.

◆ Application 4: I need a reliable edge I/O solution for remote outdoor sites (Solar, Water treatment) with no local staff. (Keywords: SCADA telemetry Modbus, remote solar water data logger)
👉 Product model: GCAN-IO-8101
💡 How it works:
➤ Role: Acts as a highly reliable edge data acquisition node for harsh environments.
➤ Connection: Deployed in outdoor or unattended cabinets, supporting an extreme operating temperature range of -40°C to +85°C.
➤ Telemetry: Gathers data from local sensors and uploads it to the central SCADA or cloud platform via Modbus TCP/RTU. The auto-configuration feature eliminates the need for on-site software programming, significantly reducing maintenance frequency and labor costs for remote sites.

Technical Specifications

Modbus Protocol
Standard Modbus TCP/RTU Slave Node. Supports standard Ethernet (10/100M) and RS485 serial communication. Seamless integration with a wide range of PLCs, SCADA, and HMI systems without brand restrictions.
I/O Expansion Capacity
Connects up to 32 GC series I/O modules. Supports mixed-signal expansion (Digital, Analog, RTD/TC). Auto-configuration automatically detects and maps connected modules with zero complex PC setup.
Communication Interfaces
1x RJ45 Ethernet port for Modbus TCP. 1x RS485 interface (485A/485B) for Modbus RTU. 1x USB port dedicated for on-site firmware upgrades.
Serial Baud Rate
Serial Baud Rate: 600bps to 115200bps. Flexible for long-distance transmission. Supports standard Modbus RTU master-slave architecture and static IP configuration for Ethernet.
Wiring & Terminals
Screwdriver-Assisted Push-in Terminals. Easy wiring for both power and RS485 communication. Dedicated +24V, 0V, and PE (Shield) terminals.
Isolation & Power
24V DC (-15%/+20%) power supply. Coupler max power consumption approx. 10W. (Note: I/O module power depends on the specific expansion modules selected).
Mounting & Form
Standard DIN-Rail Mount. Features a self-locking mechanism with an orange release tag. Compact size (104.5 x 24.1 x 74.8 mm). Requires a Bus End Terminal (GC0002).
Environmental
Built for Harsh Environments. Wide operating temperature from -40°C to +85°C. 10%~95% RH non-condensing. Pollution degree 2. Protection class IP20. Max altitude 2000m.
Note: The GCAN-IO-8101 is a Modbus Bus Coupler. The GC series I/O terminal modules (Digital, Analog, RTD/TC) must be purchased separately based on your specific channel requirements. The terminal module (Model: GC0002) is included.

Compatible I/O Expansion Modules for GCAN-I/O-8101 Modbus Remote I/O Coupler

Model Function Channels Key Parameters Required Terminal
GC-1416 Digital input, PNP/NPN (Selectable) 16 24 VDC; ON 9–30 VDC; response 3 ms; SS terminal sets all 16 ch GC-0002
GC-2416 Digital output, PNP 16 24 VDC PNP; 500 mA/ch max; 300 mA/ch simultaneous; independent supply required GC-0002
GC-2516 Digital output, NPN 16 0 VDC NPN; 500 mA/ch max; 280 mA/ch simultaneous; independent supply required GC-0002
GC-3028 Analog input, voltage 8 -10 to +10 V; 16-bit; ±0.5% FS GC-0002
GC-3058 Analog input, current 8 4–20 mA; 16-bit; ±0.5% FS GC-0002
GC-4024 Analog output, voltage 4 -10 to +10 V; 16-bit; ±1% FS; load ≥1 kΩ GC-0002
GC-4054 Analog output, current 4 4–20 mA; 16-bit; ±1% FS; load ≤400 Ω GC-0002
GC-3108 Temperature input, PT100 8 2-wire PT100; -200 to +600°C; approx. ±3°C at 25°C GC-0002
GC-3248 Temperature input, thermocouple 8 K type; -200 to +900°C; approx. ±2°C (ext.) / ±3°C (int.) at 25°C GC-0002
GC-5116 Digital input + output, PNP 8 + 8 8 PNP DI + 8 PNP DO; 24 VDC; 3 ms input response GC-0002

GCAN-IO-8101 Modbus Coupler and I/O Expansion Modules: Setup, Wiring, and Troubleshooting FAQs

Q Is the GCAN-IO-8101 compatible with my existing PLC or SCADA system? ▼

Yes. The GCAN-IO-8101 is a standard Modbus TCP/RTU Slave. As long as your PLC (e.g., Siemens, Allen-Bradley, Mitsubishi, Schneider), SCADA, or HMI acts as a Modbus Master/Client, it can seamlessly communicate with this coupler via its RJ45 Ethernet port or RS485 interface. No proprietary drivers are required.

Q Do I need to write complex software code to configure the expanded I/O modules? ▼
  • No programming is required. The GCAN-IO-8101 features Auto-Configuration.
  • Once you stack the GC series I/O modules on the right side, the coupler automatically detects the module types and maps the data into standard Modbus registers. You can simply read/write these registers using your master device without any PC-side parameter setup.
Q How does GCAN-IO-8101 map the I/O data to Modbus registers? ▼

The coupled I/O modules map directly to consecutive Modbus Holding Registers (or Coils/Discrete Inputs) based on the physical slot order. Engineers can easily read/write all distributed I/O via standard Modbus RTU/TCP function codes.

Q What is the maximum expansion capacity, and can I mix different types of I/O? ▼
  • You can connect up to 32 GC series I/O modules to a single coupler.
  • The system supports mixed-signal expansion, meaning you can freely combine Digital Inputs (DI), Digital Outputs (DO), Analog Inputs (AI), Analog Outputs (AO), and Temperature (RTD/TC) modules based on your specific project requirements.
Q How do I wire the RS485 network, and are termination resistors required? ▼
  • The 8101 uses standard RS485 (485A/485B) terminals for Modbus RTU. For network topology, you can daisy-chain multiple nodes.
  • While the coupler itself does not have built-in 120Ω resistors, standard RS485 termination rules apply: you must install a 120Ω resistor at both the very first and very last node on the bus to eliminate signal reflection.
Q What is included in the package? Do I need to buy the terminal module separately? ▼
  • The coupler comes with the required Bus End Terminal (Model: GC0002) to ensure stable GC-Bus data transmission.
  • However, the I/O expansion modules (GC series) must be purchased separately depending on your channel requirements. The terminal module must always be installed at the far right end of the assembled node.
Q How do I supply power to the coupler and the connected I/O modules? ▼
  • The coupler requires a standard 24V DC power supply (-15%/+20%). The coupler itself consumes a maximum of approx. 10W.
  • The GC-Bus technology distributes power from the coupler to the subsequent I/O modules. Please refer to the specific power consumption of your selected I/O modules to ensure your 24V power supply is adequately sized.
Q Can these I/O expansion modules be used without the GCAN-IO-8101 adapter? ▼
  • No. These 18-pin modules are expansion slices for the GCAN-IO-8101 system. They cannot operate independently.
  • A complete node requires the GCAN-IO-8101 adapter, compatible 18-pin I/O modules, and one GC-0002 bus end terminal.
Q Is GC-0002 required for every GCAN-IO-8101 node? ▼

Yes. One GC-0002 bus end terminal is required per GCAN-IO-8101 node and must be installed at the far right end. The manual explicitly states that it must be installed; otherwise, I/O devices will not work.

Q Do I need one GC-0002 for each I/O expansion module? ▼

No. One GC-0002 is required per node, not per module. It is installed once at the far right end of the entire node.

Q Can GC-0001 be used instead of GC-0002? ▼

No. GC-0001 and GC-0002 are not interchangeable. GC-0002 is for the GCAN-IO-8101 / 18-pin series. GC-0001 is for the GCAN-IO-8300 / 8/16-pin series.

Q Can I use GCAN-IO-8300 / 8/16-pin modules with the GCAN-IO-8101 adapter? ▼

No. GCAN-IO-8101 uses 18-pin modules, while GCAN-IO-8300 uses 8/16-pin modules. Do not mix the two series. For example, GC-1016, GC-3624, and GC-2016 are for the 8300 series and cannot be used on the 8101.

Q Do all digital output modules work without an external power supply? ▼

No. Note that GC-2416 and GC-2516 require an independent 24 VDC power supply. Unlike some other series, they cannot be powered solely through the internal bus. Please check the wiring diagram carefully before use.

Q How should I select between GC-1416 (PNP/NPN) for digital inputs? ▼

GC-1416 supports both PNP and NPN, but all 16 channels are switched simultaneously via the SS terminal wiring. If you need mixed PNP and NPN inputs in one node, or dedicated fixed PNP/NPN inputs, please contact us for alternative models.

Q Can I use third-party I/O modules with the GCAN-IO-8101, or use these modules with a third-party adapter? ▼

Not as standard. The adapter-to-I/O interface is the GCAN GC-Bus, not a universal standard backplane. Third-party compatibility must be confirmed by the factory before use. Do not assume plug-and-play compatibility.

Inquire Us or Request a Quote

We will get back to you shortly within 24 business hours.

Products Category Showcase
Remarks: Products are supported by CE-EMC testing in accordance with EU Directive 2014/30/EU, as well as RoHS testing in accordance with IEC 62321-3-1:2013.
Min 25 characters Max characters left: 750
📁

Upload your file (Optional)

No file chosen

Supported formats: PDF, Images (JPG, PNG, WEBP), CAD drawings (DWG, STEP, IGES), Documents (Word, Excel), ZIP, RAR, etc.

Max file size: 25MB

Got multiple files? Put all your files in a folder and compress the folder into a ZIP or RAR file.

Alternatively, send your RFQ directly to [email protected]

Security Quiz: 16 + 3 = ? *