GCAN Model: GCAN-I/O-4038

GCAN-I/O-4038 CANopen Analog Input Module

4-Ch DI & 4-Ch DO · CAN 2.0A/B & CANopen · 10K-1M Programmable Baud Rate · 1500V Isolation8-Ch AI · CAN 2.0A/B & CANopen · ±5V/±10V/±20mA · 1500V Isolation

🔵 Overview

  • The GCAN-I/O-4038 is an industrial-grade CAN/CANopen Analog Data Acquisition Module designed to highly expand analog signal acquisition capabilities over CAN networks.
  • Compliant with standard CANopen protocols (CiA 301) and CAN 2.0A/B, it acts as a reliable slave node, supporting seamless integration with a wide range of PLCs, industrial controllers, and SCADA systems.
  • Equipped with 1 CAN bus and 8 differential Analog Inputs (AI), it features 1500V DC electrical isolation and a wide operating temperature (-40°C to +85°C), ensuring robust and accurate data transmission in harsh industrial environments.

🔵 Critical Selection Guide: Expansion & Compatibility

  • Before selecting your Analog Input modules, please note the hardware configuration features for your specific application:
  • Protocol & Topology: Supports standard CANopen mode (NodeID and Baud Rate configured via DIP switches) and generic CAN mode. Note: The internal 120Ω terminal resistor is NOT integrated; if needed, add it externally between CAN_H and CAN_L.
  • Wiring & Power: Pluggable screw terminals for easy wiring. Powered by 9~30V DC (24V standard recommended) with low power consumption (Max 140mA, silent state 40mA). Supports 2-wire differential input for high noise immunity.
  • I/O Capabilities: 8-Ch Analog Inputs supporting three selectable modes: ±5V, ±10V, and ±20mA (configured via SDO commands, default is ±10V). Important: For the ±20mA current mode, internal jumper caps must be connected (can be pre-configured at the factory upon request).
  • PLC Compatibility: Universally compatible as a CANopen slave node for almost all industrial controllers that support the protocol. Data is easily accessed via TPDO (Transmit Process Data Object).

🔵 Core Application Scenarios & Solutions
💡 Scenario 1: Long-Distance Analog Sensor Data Acquisition
😟 The Challenge: In large factory floors, sensors (such as pressure or temperature transmitters) are often located far from the central PLC. Running long analog cables results in severe signal attenuation and high susceptibility to Electromagnetic Interference (EMI), leading to inaccurate readings.
🖊️ The Solution: Install the GCAN-I/O-4038 locally near the field sensors. It gathers the analog signals, converts them to digital values, and transmits them reliably to the central control system via a single, highly anti-interfering CAN bus cable. This guarantees data accuracy and saves cable costs.

💡 Scenario 2: Legacy Equipment Retrofit & Upgrade
😟 The Challenge: Upgrading older machinery that relies on legacy analog sensors to a modern digital network (like CANopen or PLCs) often requires replacing the sensors entirely, which is extremely expensive and time-consuming.
🖊️ The Solution: The GCAN-I/O-4038 acts as the perfect bridge. It directly connects to the legacy analog sensors (Voltage or Current), digitizes the data, and seamlessly integrates the old equipment into a modern CANopen control architecture, drastically extending the machine's lifespan.

💡 Scenario 3: Distributed Data Monitoring in Harsh Environments
😟 The Challenge: Applications like oil fields, mining, or smart building systems require monitoring scattered analog signals under extreme temperatures or electrical noise, where standard commercial modules fail or require bulky control cabinets.
🖊️ The Solution: With its DIN-rail mount, -40°C to +85°C wide temperature range, and 1500V DC isolation, the 4038 can be deployed directly in the field. Multiple 4038 modules can be daisy-chained on the same CAN network (up to 127 nodes), creating a highly scalable and robust distributed monitoring system.

PART / MODEL IDENTIFICATION & TECHNICAL DOSSIER Part / Model No.: GCAN-I/O-4038

GCAN-4038: 8-Channel Analog Input (±5V/±10V/±20mA) to CANopen.

KEY FEATURE

CANopen Analog Input Module

8-Ch Analog Input (±5V/±10V/±20mA) for high-precision data acquisition
Standard CANopen (CiA 301) and CAN 2.0A/B protocol support
Single CAN bus interface with 1500V DC electrical isolation
Configurable input modes and data mapping via standard SDO commands
Wide 9~30V DC power input (24V standard recommended)
Industrial-grade reliability with operating temp. from -40°C to +85°C
Compact design with pluggable screw terminals for quick wiring

Find Your CANopen Remote I/O Solution by Application

🔷 Find Your CANopen Analog Input Solution by Application
◆ Application 1: My PLC or machine lacks built-in analog input channels, and I need flexible, high-precision data acquisition over the CAN network.
(Keywords: CANopen Analog Input expansion, PLC analog acquisition, distributed data monitoring)
✍️ Product model: GCAN-I/O-4038
💡 How it works:
➤ Role: Acts as a standard CANopen Analog Input Slave node for industrial automation systems.
➤ Connection: Connects seamlessly to your main PLC or controller via the isolated CAN bus (CAN_H and CAN_L terminals). It can be daisy-chained with other CANopen devices across the factory floor.
➤ Data Processing: The master system simply reads the analog values (16-bit resolution) via TPDO. Input ranges (±5V, ±10V, ±20mA) and data mapping positions are easily configured using standard SDO commands without complex re-programming.

◆ Application 2: The analog sensors (e.g., pressure, temperature, or flow transmitters) are far away from the main control cabinet, and direct long-distance analog wiring is too expensive and prone to interference.
(Keywords: remote analog data acquisition, harsh environment, 4-20mA CANopen, isolated analog input)
✍️ Product model: GCAN-I/O-4038
💡 How it works:
➤ Role: Acts as a decentralized field-level Analog Input node for remote monitoring.
➤ Connection: Installed locally near the field sensors (e.g., in coal mines, oil wells, or large factory zones). Utilizes a single twisted-pair cable for CAN communication, significantly reducing expensive multi-core analog cable costs.
➤ Signal Transmission: Field analog signals (±10V or 4-20mA) are collected locally. With 2-wire differential inputs, 1500V DC electrical isolation, and a wide operating temperature range (-40°C to +85°C), it ensures highly accurate and stable data transmission in noisy and extreme industrial environments.

◆ Application 3: Building a process control or SCADA system that requires centralized management of continuous variables like tank levels, valve positions, or environmental conditions.
(Keywords: process control CANopen, smart building analog monitoring, SCADA analog integration)
✍️ Product model: GCAN-I/O-4038
💡 How it works:
➤ Role: Serves as a high-density data acquisition front-end for SCADA or DCS systems.
➤ Connection: Easily mounts on a standard DIN rail inside control cabinets. Multiple 4038 modules can be networked together via CANopen.
➤ System Integration: Converts physical analog signals into digital data and transmits them cyclically to the master controller. Supports standard CiA 301 protocol, ensuring universal compatibility with most industrial controllers. (Note: For the 4-20mA/±20mA current input mode, internal jumper caps must be connected, which can be pre-configured at the factory.)

Technical Specifications

Fieldbus Protocol
CAN 2.0A/B (ISO/DIS 11898) & Standard CANopen (CiA 301). Operates as a reliable slave node.
Analog Input Channels
8-Channel Analog Input (Independent differential inputs). Supports ±5V, ±10V, ±20mA (Selectable via SDO). Resolution: 16-bit.
Communication Interfaces
1x CAN Bus (via 1 pluggable 4-pin terminal). Includes hardware DIP Switches for Node ID & Baud Rate configuration.
CAN Baud Rate / Node ID
Baud Rate: 10Kbps to 1Mbps programmable (Default: 500Kbps). Node ID: 1~127 (Default: 1). Configurable via DIP Switch
Wiring / Power
Pluggable screw terminals for easy wiring of AI, Power, and CAN. Power: 9~30V DC (24V standard). Max current: 140mA (Silent: 40mA).
Isolation / Protection
1500V DC electrical isolation on the CAN interface and analog input. Protects the module from transient overvoltage and overcurrent.
Mounting / Form
Size: 122 x 70 x 25 mm (approx. 110g). DIN-Rail mounting (with bracket). No internal 120Ω terminal resistor (requires external addition).
Environmental
Operating Temp: -40°C to +85°C. Humidity: 15%~90% RH non-condensing. Protection class: IP20. EMC: EN 55024, EN 55022.
Note: The 120Ω CAN bus terminal resistor is NOT integrated. If the module is the end node on the network, an external 120Ω resistor must be added between CAN_H and CAN_L. For the ±20mA/4-20mA current input mode, internal jumper caps must be connected (can be pre-configured at the factory upon request).

Choose the Right Remote I/O for Your Application

Model Bus Protocol Module Type I/O Configuration Signal Type Terminal Type Key Application / Feature
GCAN-4128 CANopen / CAN Compact (Micro) 4 DI / 4 DO Digital Screw Terminals Ultra-compact digital I/O for tight spaces; supports standard CAN & CANopen.
GCAN-4032 CANopen Compact 16 DI / 16 DO Digital Spring-Cage High-density digital I/O; ideal for standard 24V switch/actuator control.
GCAN-4038 CANopen Compact 8 AI (Differential) Analog Screw Terminals High-precision analog data acquisition (-10~+10V, -20~+20mA, etc.).
GCAN-5032 EtherCAT Compact 16 DI / 16 DO Digital Spring-Cage High-speed real-time digital I/O for motion control and EtherCAT networks.
GCAN-IO-8101 Modbus TCP/RTU Modular Coupler Expandable (0 local I/O) Mixed (via slices) Spring-Cage (GC-Bus) Head coupler for Modbus networks; supports up to 32 GC series I/O slices.
GCAN-IO-8300 Profinet Modular Coupler Expandable (0 local I/O) Mixed (via slices) Spring-Cage (GC-Bus) Pure Profinet coupler for Siemens PLCs; max 340 bytes IN/OUT, up to 32 slices.

Inquire Us or Request a Quote

We will get back to you shortly within 24 business hours.

Products Category Showcase
Remarks: Products are supported by CE-EMC testing in accordance with EU Directive 2014/30/EU, as well as RoHS testing in accordance with IEC 62321-3-1:2013.
Min 25 characters Max characters left: 750
📁

Upload your file (Optional)

No file chosen

Supported formats: PDF, Images (JPG, PNG, WEBP), CAD drawings (DWG, STEP, IGES), Documents (Word, Excel), ZIP, RAR, etc.

Max file size: 25MB

Got multiple files? Put all your files in a folder and compress the folder into a ZIP or RAR file.

Alternatively, send your RFQ directly to [email protected]

Security Quiz: 26 - 10 = ? *