GCAN Model: GCAN-204

GCAN-204 Modbus RTU Slave to CAN Gateway

Level 3 Gateway: Register Mapping Modbus RTU Slave to CAN Gateway · CAN 2.0A/B · Configurable Data Mapping · Software Configuration

Overview : Level 3 — Register Mapping

  • The GCAN-204 is an industrial Modbus RTU Slave to CAN gateway, enabling bidirectional data exchange between Modbus RTU master devices and CAN networks.
  • It maps CAN data to Modbus registers, allowing PLCs, HMIs and other Modbus RTU master devices to read CAN data and send data to CAN devices through standard Modbus commands.
  • With configurable data mapping and communication parameters, the GCAN-204 simplifies integration between Modbus RTU-based control systems and CAN-connected devices.
PART / MODEL IDENTIFICATION & TECHNICAL DOSSIER Part / Model No.: GCAN-204

The GCAN-204 is an industrial Modbus RTU slave to CAN gateway with RS485 and CAN interfaces, designed for DIN-rail mounting and protocol conversion between an existing Modbus master and CAN devices.

KEY FEATURES

Modbus RTU Slave to CAN Gateway

Level 3 Gateway: Register Mapping
Designed for seamless industrial protocol conversion
1x RS485 and 1x CAN 2.0A/2.0B interface
1500V DC isolation on CAN side
Operating Temp. at -40°C to +85°C
Free config software with zero programming.

01. Modbus RTU Slave Operation

Operates exclusively as a Modbus RTU Slave, responding to requests from an external Modbus master such as a PLC or HMI. It does not support active Modbus device polling.

02. Passive CAN Data Acquisition

Receives and buffers CAN bus data, making it available for the Modbus master to read through mapped registers.

03. Modbus-to-CAN Data Transmission

Allows the Modbus master to write data to mapped registers, triggering transmission of corresponding data to the CAN network.

04. Configurable Register Mapping

Configures the mapping between CAN data and Modbus registers to match application requirements.

05. Standard Modbus Function Codes

Supports Modbus RTU function codes 03H, 04H, 06H and 16H for register reading and writing.

06. CAN 2.0A/B Compatibility

Supports standard CAN 2.0A and 2.0B communication, with configurable baud rates from 5 kbps to 1 Mbps.

07. Data Conversion Throughput

Supports data conversion at up to 400 CAN frames per second for Modbus-CAN communication.

08. PC-Based Software Configuration

Configure communication parameters and data mapping through dedicated Windows configuration software. Settings are stored in non-volatile memory.

09. Industrial Power Supply & Isolation

Operates on a 9–24 V DC power supply and provides 1500 V DC electrical isolation between communication interfaces.

Find Your Gateway Solution by Application

◆ Application 1: PLC-Based CAN Device Data Acquisition
💡 How it works:

  • Role: Acts as a Modbus RTU Slave, providing CAN bus data to a PLC or other Modbus RTU master.
  • Connection: Connects the CAN network to a PLC through the Modbus RTU communication interface.
  • Data Processing: Receives and buffers CAN frames, maps the data to Modbus registers, and makes it available when requested by the PLC.

◆ Application 2: PLC-to-CAN Device Command Transmission
💡 How it works:

  • Role: Serves as a communication bridge for transmitting PLC commands to CAN-connected devices.
  • Connection: The PLC writes data to the GCAN-204 through Modbus RTU, while the gateway connects to the target CAN devices.
  • Signal Transmission: Converts the mapped Modbus register data into CAN frames and transmits them to the CAN network.

◆ Application 3: CAN Device Integration into Modbus RTU Automation Systems
💡 How it works:

  • Role: Integrates CAN-based equipment into existing Modbus RTU-based automation systems.
  • Connection: Connects CAN devices to a PLC or HMI through the GCAN-204 and Modbus RTU communication.
  • Data Processing: Maps CAN data to Modbus registers, allowing the host system to access CAN device data using standard Modbus RTU commands.

Gateway Selection Guide: Semantic Depth & Master/Slave Capability

Model Semantic Processing Level CAN-Side Role Can it act as a Master? Sub-models / Programmability Interfaces Application
GCAN-204 Register mapping (Not transparent) Fixed Modbus RTU Slave No. Modbus RTU Slave only. Single fixed firmware. Free config software, zero programming. 1× RS485,
1× CAN 2.0A/B
PLC/HMI (Modbus master) reading CAN sensors; legacy retrofits.
GCAN-205 Register mapping (Not transparent). Fixed Modbus TCP Slave No. Modbus TCP Slave only. Single fixed firmware. Free config software. 1× Ethernet,
1× CAN 2.0A/B
SCADA/HMI reading CAN devices over Ethernet.
GCAN-208 Pure physical-layer passthrough. No protocol role No. No protocol stack. Sub-models: 208-1, 208-2, 208-2F. 1–2× Fiber,
1–2× CAN 2.0A/B
Long-distance CAN extension, high EMI isolation.
GCAN-211
Socket-level transparent transmission. No protocol role No. Data pipe only. Single unit. Can work in pairs as a wireless CAN repeater. 2× CAN,
1× Ethernet,
1× WiFi
Wireless CAN access, mobile debugging.
GCAN-212B Socket-level transparent transmission. No protocol role No. Data pipe only. Single unit (DIN-rail). 2× CAN,
1× Ethernet
Dual-channel CAN to Ethernet inside cabinets.
GCAN-GT-8221 Splits by sub-model: EtherCAT Slave → CAN:
No on EtherCAT side. Fixed EtherCAT slave.
Sub-models: -CAN, -COM. Fixed firmware. 2× EtherCAT (daisy-chain),
1× CAN
EtherCAT PLC integrating existing CANopen slave devices.
• -CAN: Raw passthrough. • -CAN: Passthrough
• -COM: CANopen slave stack (Semantic parsing). • -COM: CANopen Slave
GCAN-GT-8321 Splits by sub-model (Most comprehensive): Profinet Slave → CAN: Profinet side: No. Sub-models: -CAN, -COM, -COS, -MRTUM, -MRTUS, -MTCPS, -PROG. 2× Profinet,
1× CAN,
1× RS485,
1× Ethernet (varies)
Siemens PLC integrating CANopen drives; active CANopen network management.
• -CAN: Raw passthrough. • -CAN: Passthrough CAN side:  NO
• -COM: CANopen Slave. • -COM: CANopen Slave CAN side:  NO
• -COS: CANopen Master (NMT, node monitoring). • -COS: CANopen Master CAN side: -COS YES
• -PROG: Programmable. User-defined (Master/Slave configurable) Yes (Configurable via program)
GCAN-GT-415 Full programmable semantic processing. Configurable via program Yes, fully configurable. CANopen & Modbus Master/Slave. No fixed sub-models. Programmable via OpenPCS (IEC 61131-3). 2× CAN, Ethernet, RS485, RS232, 4G, WiFi Multi-protocol mixing, non-standard logic, remote upload (acts as a mini-PLC).

 

GCAN-204 Technical FAQ: Modbus RTU Slave to CAN Integration & Troubleshooting

Q Can GCAN-204 function as a Modbus RTU Master? ▼

No. The GCAN-204 is strictly a Modbus RTU Slave device. It cannot actively poll or manage other Modbus devices. It is designed to wait for read/write requests from an existing Modbus Master (such as a PLC, HMI, or SCADA system) and translate those requests into CAN frames.
(If you need a gateway to actively poll Modbus devices or act as a CANopen Master, please refer to our Level 4 or Level 5 gateways.)

Q How does the Zero-Coding CAN-to-Register Mapping work? ▼

Unlike basic passthrough gateways that just move raw data, the GCAN-204 operates at Level 3 (Register Mapping). It extracts the payload from specific CAN IDs and maps them directly into standard Modbus registers.
Using our free configuration software, you simply define which CAN ID corresponds to which register address. Your PLC can then read the data directly using standard Modbus function codes (03H, 04H, 06H, 16H) without writing any host-side parsing code.

Q Why does my PLC read raw Hex data instead of a physical value (e.g., 25.5°C)? ▼

Because gateways handle protocol-level semantics, not physical quantity semantics. The GCAN-204 accurately translates the byte structure from the CAN frame into the Modbus register, but it does not know if the raw data represents temperature, RPM, or voltage.
The physical scaling and engineering units (e.g., dividing by 100 to get 25.5°C) must be configured inside your upper-level system (PLC or HMI).

Q Do I need a 120Ω termination resistor for the CAN bus? ▼

Yes. A standard CAN bus requires exactly two 120Ω terminal resistors, installed at the two furthest physical ends of the bus (connected between CAN_H and CAN_L). Without them, signal reflections will occur, leading to data loss, error frames, and unstable communication—especially at higher baud rates (e.g., 500 Kbps or 1 Mbps).

Q What is the Maximum Data Conversion Throughput (fps)? ▼

The GCAN-204 supports a maximum data conversion rate of 400 frames per second (fps) per CAN channel. This maximum rate is achieved when the RS485 serial baud rate is set to 115200 bps. This throughput is highly sufficient for standard industrial data acquisition, parameter monitoring, and control command delivery.

Inquire Us or Request a Quote

We will get back to you shortly within 24 business hours.

Products Category Showcase
Remarks: Products are supported by CE-EMC testing in accordance with EU Directive 2014/30/EU, as well as RoHS testing in accordance with IEC 62321-3-1:2013.
Min 25 characters Max characters left: 750
📁

Upload your file (Optional)

No file chosen

Supported formats: PDF, Images (JPG, PNG, WEBP), CAD drawings (DWG, STEP, IGES), Documents (Word, Excel), ZIP, RAR, etc.

Max file size: 25MB

Got multiple files? Put all your files in a folder and compress the folder into a ZIP or RAR file.

Alternatively, send your RFQ directly to [email protected]

Security Quiz: 5 + 5 = ? *